Standard Kit
-
- Unit

-
- Lithium battery (inserted into a tube)

-
- User's Manual

-
- Strap

This Standard Kit is designed exclusively for: RTR-501, 501L, 502, 502L, 503, 503L, 505, and 505L. See below for the RTR-574 Standard Kit.
RTR-501 / 501L
Standard Kit only
RTR-502 / 502L
Standard Kit + TR-5106
RTR-503 / 503L
Standard Kit + TR-3310
RTR-505-TC / 505-TCL
Standard Kit + Thermocouple Module (TCM-3010)
RTR-505-Pt / 505-PtL
Standard Kit + PT Module (PTM-3010)
RTR-505-V / 505-VL
Standard Kit + Voltage Module (VIM-3010)
RTR-505-mA / 505-mAL
Standard Kit + 4-20mA Module (AIM-3010)
RTR-505-P / 505-PL
Standard Kit + Pulse Input Cable (PIC-3150)
Standard Kit for RTR-574
Setup
Optional Temperature Sensors for RTR-502/502L
Materials: (1)Thermistor, (2) Stainless pipe (SUS316), (3) Fluoropolymer Compaction Tube, (4) Fluoropolymer Coated Electrical Wire, (5) Fluoropolymer Coated Mold
Possible Temperature Measurement Range:- 60 to 155°C,
Sensor Temperature Resistance: -70 to 180°C
Temp Measurement Accuracy:
Average ±0.3°C(-20 to 80°C) , Average ±0.5°C (-40 to -20°C / 80 to 110°C),
Average ±1.0°C (-60 to -40°C / 110 to 155°C)
TR-5101 (Fluoropolymer Coated Sensor)
Cable Length: 45mm (1.8in)
Thermal Time Constant:
Approx. 30 Sec. (in air)
Unit: mm
TR-5106 (Fluoropolymer Coated Sensor)
Cable Length: 0.6m (24in)
Thermal Time Constant:
Approx. 30 Sec. (in air)
Approx. 4 Sec. (in agitated water)
Unit: mm
TR-5220 (Stainless Protection Sensor)
Cable Length: 2.0m (80in)
Thermal Time Constant:
Approx. 36 Sec. (in air)
Approx. 7 Sec. (in agitated water)
Unit: mm
TR-5320 (Stainless Protection Sensor)
Cable Length: 2.0m (80in)
Thermal Time Constant:
Approx. 12 Sec. (in air)
Approx. 2 Sec. (in agitated water)
Unit: mm
TR-5420 (Stainless Protection Sensor)
Cable Length: 2.0m (80in)
Thermal Time Constant:
Approx. 12 Sec. (in air)
Approx. 2 Sec. (in agitated water)
Unit: mm
TR-5530 (Water Immersible Sensor)
Thermal Time Constant:
Approx. 120 Sec. (in air)
Approx. 6 Sec. (in agitated water)
Unit: mm
Temperature Sensor Extension Cable for RTR-502/502L
Materials: (1)Vinyl Coated Electrical Wire
TR-2C30 (Only use for Temperature Sensors for RTR-502/502L)
Splash Resistant (IP64)
An error of about +0.3°C occurs at normal temperature while an error of about +0.5°C will occur at around -50°C.
Unit: mm
Temperature / Humidity Sensor for RTR-503/503L
Materials: (1)Temperature/Humidity sensor, (2) Polypropylene resin, (3) Vinyl Coated Electrical Wire
TR-3310
Cable Length: 1m(27.5in)
Possible Temperature Measurement Range: 0 to 55°C
Possible Humidity Measurement Range: 10 to 95%RH
Sensor Temperature Resistance: -10 to 60°C
Sensor Response Time: About 7 min. (90% response)
Temp Measurement Accuracy: Average +/-0.3°C
Humidity Measurement Accuracy: +/-5%RH (At 25°C, 50%RH)
Operational Conditions: Without dew condensation, water leakage or effect from corrosive gas or organic solvents.
The service life of humidity sensors can vary greatly depending on operating environment. Periodic calibration may be required.
Unit: mm
Input Module for RTR-505-TC
TCM-3010 (Thermocouple Module)
| |
TCM-3010 |
| Measurement Item |
Temperature |
| Compatible Sensors |
Thermocouple: Type K, J, T, S |
| Measurement Range |
-199 to 1700°C (within the sensor heat-durability range only) |
| Measurement Resolution |
Type K, J, T : 0.1°C Type S : about 0.2°C |
| Measurement Accuracy (*1) |
Cold Junction Compensation |
Module temperature at 10 to 40°C: ±0.3°C, At other temp: ±0.5°C |
| Thermocouple Measurement |
Type K, J, T : ±0.3°C + 0.3% of reading Type S : ±1°C + 0.3% of reading |
| Sensor Connection |
Miniature Thermocouple Connector(*2) |
| Operating Environment |
Temperature: -40 to 80°C, Humidity: 90%RH or less (no condensation) |
(*1) Sensor error is not included.
(*2) Make sure to use a thermocouple sensor with a miniature thermocouple plug attached. T&D does not make available these plugs or sensors for sale.
Materials: (1)Polyamide (black), (2)Vinyl Coated Electrical Wire
Unit: mm
Input Module for RTR-505-Pt
PTM-3010 (Pt Module)
| |
PTM-3010 |
| Measurement Item |
Temperature |
| Compatible Sensors |
Pt100 (3-wire), Pt1000 (3-wire) |
| Measurement Range |
-199 to 600°C (within the sensor heat-durability range only) |
| Measurement Resolution |
0.1°C |
| Measurement Accuracy (*1) |
Module temperature at 10 to 40°C: ± 0.3°C + 0.3% of reading At other temp: ±0.5°C + 0.3% of reading |
| Sensor Connection |
Screw Clamp Terminal Block: 3-Terminal |
| Operating Environment |
Temperature: -40 to 80°C, Humidity: 90%RH or less (no condensation) |
| Accessories |
Protection Cover |
(*1) Sensor error is not included.
Materials: (1)Polyamide (black) (2)Vinyl Coated Electrical Wire
Unit: mm
Input Module for RTR-505-V
VIM-3010 (Voltage Module)
| |
VIM-3010 |
| Measurement Item |
Voltage |
| Input Voltage Range |
0 to 999.9mV, 0 to 22V Breakdown voltage: ±28V |
| Measurement Resolution |
up to 400mV: at 0.1mV, up to 800mV: at 0.2mV, up to 999.9mV: at 0.4mV, up to 3.2V: at 1mV, up to 6.5V: at 2mV, up to 9.999V: at 4mV, up to 22V: at 10mV |
| Measurement Accuracy |
Module temperature at 10 to 40°C: ± 0.5mV + 0.3% of reading At other temp: ±1mV + 0.5% of reading |
| Input Impedance |
mV Range: About 3MΩ, V Range: About 1MΩ |
| Preheat Function |
Voltage Range (Preheating): 3V to 20V100mA, Time Range (Preheating): 1 to 999 seconds (in units of one-second) Diode for backflow prevention built in the "Preheat OUT" side |
| Sensor Connection |
Cable Insertion Connection: 4-Terminal |
| Compatible Wires |
Single wire: φ0.32 to φ0.65mm (AWG28 to AWG22), φ0.65mm (AWG22) recommended Twisted wire: 0.32mm2 (AWG22), φ0.12mm or more in diameter Strip length: 9 to 10mm |
| Operating Environment |
Temperature: -40 to 80°C, Humidity: 90%RH or less (no condensation) |
Materials: (1)Polyamide (black), (2)Vinyl Coated Electrical Wire

Unit: mm
Input Module for RTR-505-mA
AIM-3010 (4-20mA Module)
| |
AIM-3010 |
| Measurement Item |
4-20mA |
| Input Current Range |
0 to 20mA (Operational up to 40mA) |
| Measurement Resolution |
0.01mA |
| Measurement Accuracy |
Module temperature at 10 to 40°C: ± 0.05mA + 0.3% of reading At other temp: ±0.1mA + 0.3% of reading |
| Input Resistance |
100Ω ±0.3Ω |
| Sensor Connection |
Cable Insertion Connection: Plus(+) 2 Parallel Terminals, Minus(-) 2 Parallel Terminals: Total 4 Terminals |
| Compatible Wires |
Single wire: φ0.32 to φ0.65mm (AWG28 to AWG22), φ0.65mm (AWG22) recommended Twisted wire: 0.32mm2 (AWG22), φ0.12mm or more in diameter Strip length: 9 to 10mm |
| Operating Environment |
Temperature: -40 to 80°C, Humidity: 90%RH or less (no condensation) |
Materials: (1)Polyamide (black), (2)Vinyl Coated Electrical Wire
Unit: mm
Input Module for RTR-505-P
PIC-3150 (Pulse Input Cable)
| |
PIC-3150 |
| Measurement Item |
Pulse |
| Input Voltage Range |
0 to 27V Breakdown voltage: -5V, +27V |
| Detection Voltage |
Lo: 0.5V or less, Hi: 2.5V or more |
| Chattering Filter |
ON (15Hz or less) / OFF (3.5kHz or less) 0-3V Rectangular Wave Signal |
| High Level Pulse Width |
Chattering Filter ON: 35ms or more, Chattering Filter OFF: 180μs or more |
| Low Level Pulse Width |
Chattering Filter ON: 12ms or more, Chattering Filter OFF: 100μs or more |
| Response Polarity |
Select either Lo→Hi or Hi→Lo |
| Maximum Count |
61439 / Recording Interval |
| Input Impedance |
About 100kΩ |
| Max Jitter |
Normal: About 0.01 seconds, During Communication: About 0.1 seconds |
Materials: (1) M3.5 Crimp Terminal, (2) Vinyl Coated Electrical Wire
Unit: mm
Sensors for RTR-574
ISA-3151 (Illuminance UV Sensor)
| |
ISA-3151 |
| Measurement Items |
Illuminance |
UV Intensity |
| Measurement Range |
0 to 130,000lx |
0 to 30mW/cm2 |
| Measurement Resolution |
Minimum: 0.01 lx |
Minimum: 0.001 mW/cm2: |
| Measuring Accuracy |
10 to 100,000 lx:
±5%(*1)
(at 25°C and 50%RH) |
0.1 to 30 mW/cm2
±5%(*1)
(at 25°C and 50%RH) |
Relative Spectral Response |
(*2) |
260 to 400 nm |
Cosine Correction (cosΘ) |
(*3) |
- |
Operating Environment |
Temperature: -10 to 60°C Humidity: 90%RH or less (no condensation) |
| Conditions for Use |
Do not expose to condensation, dampness, corrosive gases or organic solvents |
| Sensor Dimensions |
H23 x W65 x D12.6 mm |
| Cable Length |
1.5 m |
(*1) Compared to the value measured by the T&D standard sensor for calibration under our calibration light source.
(*2) Approximated to the CIE standard response function V (λ).
(*3) Within ±1.5% at 10°; Within ±3% at 30°; Within ±10% at 60°; Within ±30% at 80°
Materials:(1)Polycarbonate (2)Glass (3)Vinyl chloride-shielded wire
Unit: mm
THA-3151 (Temperature/Humidity Sensor)
| |
THA-3151 |
| Measurement Items |
Temperature |
Humidity |
| Measurement Range |
0 to 55°C |
10 to 95%RH |
| Measurement Resolution |
0.1°C |
1%RH |
| Measuring Accuracy |
Avg. ±0.3°C |
±5%
(at 25°C and 50%RH) |
Sensor Response Time |
About 7 min. (90%) |
| Humidity Hysteresis |
- |
±1%RH
(30 to 90%RH) |
Operating Environment |
Temperature: 0 to 55°C Humidity: 95%RH or less (no condensation) |
| Conditions for Use |
Do not expose to condensation, dampness, corrosive gases or organic solvents |
| Sensor Dimensions |
H18 x W51.5 x D10 mm |
| Cable Length |
1.5 m |
Materials:(1)Polycarbonate (2)Vinyl chloride-shielded wire
Unit: mm
HHA-3151 (Temperature/Humidity Sensor-High-Precision Type)
| Measurement Items |
Temperature |
Humidity |
| Measurement Range |
-30 to 80°C |
0 to 99%RH |
| Measurement Resolution |
0.1°C |
0.1 %RH |
| Measurement Accuracy |
±0.3°C (at 10 to 40 °C)
±0.5°C (at all other temperatures) |
±2.5 %RH(at 25 °C, 10 to 85 %RH)
±4.0 %RH(at 25 °C, 0 to 10 % or 85 to 99 %RH)
At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. |
| Response Time (90%) |
Approx. 7 min. |
Approx. 20 sec. |
| Sensor Temperature Durability |
-30 to 80°C |
| Long Term Stability |
±1%RH/yr, ±0.1°C/yr |
| Humidity Hysteresis |
- |
1.5%RH or lower (*1) |
| Sensor Dimensions |
H 19 mm x W 65 mm x D 10 mm |
| Cable Length |
1.5 m |
| Conditions for Use |
Do not expose to condensation, dampness, corrosive gases or organic solvents |
|
*1: When used at temperatures equal to or higher than 0°C. |
Materials: ①Polycarbonate ②Vinyl chloride-shielded wire
Unit: mm
TR-1C30 (Sensor Extension Cable for RTR-574)
Up to 3 extension cables can be connected to one sensor (Temperature/Humidity Sensor THA-3151 and Illuminance UV Sensor ISA-3151).
Cable Length: 3 m
Temperature Durability: -25~60°C
Material: Vinyl chloride-shielded wire
Unit: mm
Wall Attachment
TR-05K3 for RTR-501/502/503
(1)Lock screws (2)Polycarbonate (3)Double-sided Adhesive tape
Dimension (mm):
- W66.6 x H70 x D24.7
- Screw Holes: 2 - Φ4.2
Operational Environment Temp:
-40 to 80°C
*NOTE: Cracks may develop if exposed to strong impact at temperatures of -30°C or less.
Unit: mm
TR-05K3L for RTR-501L/502L/503L
(1)Lock screws (2)Polycarbonate (3)Double-sided Adhesive tape
Dimension (mm):
- W66.6 x H70 x D51.7
- Screw Holes: 2 - Φ4.2
Operational Environment Temp:
-40 to 80°C
*NOTE: Cracks may develop if exposed to strong impact at temperatures of -30°C or less.
Unit: mm
TR-07K2 (for RTR-574)
Included:
Wall Mount Screws x 2
Double-Sided Adhesive Tape x 1
Unit: mm
Others (Maintenance / Power) for RTR-501/502/503
Unit: mm
TR-00P1 (Maintenance Set)
Contents:
- Rubber Packing x 1
- Silica Gel x 1
- Double-sided Adhesive Tape x 1
- Lock Screw x 2
Unit: mm
TR-11P2 (Battery Set for Low-Temperature Use)
Contents:
- Lithium battery SAFT(LS14250) x 1
- Tube x 1
- Maintenance Set (TR-00P1) x 1
Unit: mm
RTR-500A1 (External Power Adaptor Kit)
Voltage Input: DC6V
Back-up Power: Ni-MH Battery (In case of power loss)
Back-up Time: 4 days (*1)
Charging Method: Trickle Charge
Operating Temperature: 0 to 60°C
Waterproof Capacity: None
Weight: about 37g (without AC Adaptor)
Kit Contents:
- External Power Adaptor x 1
- AC Adaptor (AD-0638 or AD-0638-C) x 1
- Attachment hook x 1
- Rubber Packing (small) x 1 (for AC Adaptor jack)
- Maintenance Set (TR-00P1)
(*1) Battery Life varies depending on measuring environment, recording interval, transmission frequency, and ambient temperature. The battery life estimated here is calculated using a new battery under normal operating conditions and in no way should be understood as a guarantee of battery life.
Unit: mm
RTR-500B1 (Large Capacity Battery Kit )
Power: Lithium Battery x 1 (LS26500) (*1)
Battery Life: about 4 years (*2)
Waterproof Capability: Splash proof
Operating Temperature: -40 to 80°C (*3)
Weight: about 75g (including Lithium Battery)
Kit Contents:
- Large Capacity Battery Adaptor x 1
- Attachment hook x 1
- Maintenance Set (TR-00P1)
(*1) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
(*2) Battery Life varies depending on measuring environment, recording interval, transmission frequency, and ambient temperature. The battery life estimated here is calculated using a new battery under normal operating conditions and in no way should be understood as a guarantee of battery life.
(*3) Operating temperature depends on the specifications for the data logger being used.
Unit: mm
Options for RTR-574
US-15C (USB Communication Cable)
Cable Length: 1.5 m
Unit: mm