| FCC model / CE model | RTR-501/501L |
RTR-502/502L |
RTR-503/503L |
|---|---|---|---|
| Number of Channels | 1 Ch (Temperature) | 1 Ch (Temperature) | 2 Ch (1 Temperature and 1 Humidity channel) |
| Sensor | Internal Temp. Sensor | External Temp. Sensor (TR-5106) | External Temp. and Humidity Sensor (TR-3310) |
| Unit of Measurement | °C, °F | °C, °F | °C, °F, % |
| Thermal Time Constant | 15 min. L Type: 25 min. |
Approx. 15 sec. (in air) Approx. 2 sec. (in agitated water) |
- |
| Sensor Response Time | - | - | About 7 min. (90% response) |
| Measurement Range | - 40 to 80 °C | - 60 to 155 °C | 0 to 55 °C 10 to 95%RH |
| Measurement Accuracy | Avg±0.5°C | Avg±0.3°C (-20 to 80°C) Avg±0.5°C (-40 to -20°C / 80 to 110°C) Avg±1.0°C (-60 to -40°C / 110 to 155°C) |
Avg±0.3°C ±5%RH (at 25°C and 50%RH) |
| Measurement Display Resolution | 0.1°C | 0.1°C | 0.1°C / 1%RH |
| Recording Intervals | Select from 15 choices: 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min. |
||
| Logging Capacity | 16,000 readings | 8,000 data sets (One data set consists of readings for all channels in that type of unit.) | |
| Recording Mode | Endless : Upon reaching logging capacity, the oldest data is overwritten and recording continues. One-time: Upon reaching logging capacity, recording will automatically stop. * When using RTR-500GSM, RTR-500NW or RTR-500AW as a Base Unit, only "Endless" can be selected. |
||
| LCD Display Items | Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Amount of Recorded Data, Unit of Measurement |
||
| Power | Lithium Battery (LS14250 (SAFT)) x 1 for L type: Large Capacity Battery Adaptor Kit(RTR-500B1 / sold separately) (*1) / External Power Adaptor Kit(RTR-500A1 / sold separately) |
||
| Battery Life (*2) | About 10 months L Type: About 4 years |
||
| Radio Standard Specifications | FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz) ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz) |
||
| Wireless Transmission Range | About 150 meters (500ft) if direct and unobstructed. | ||
| Communication Interfaces | Short Range Radio Communication Optical Communication |
||
| Communication Time | When downloading one Remote Unit at full logging capacity: Wireless communication : about 2 min.(*3) Optical communication : about 160 sec. |
||
| Water Resistance | immersion proof | splash proof(*4) | |
| Dimensions | H62mm x W 47mm x D19mm(excluding protrusions) L Type: with Large Capacity Battery Pack D 46.5mm Antenna length 24mm |
||
| Weight | About 56g (including 1 lithium battery) L Type: about 109g (with Large Capacity Battery Pack) |
||
| Unit Temp. Resistance | -30 to 80°C (Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C ) | ||
| Others | In order to download data via wireless communication, it is necessary to purchase Base Unit: RTR-500, RTR-500GSM, RTR-500NW/500AW or RTR-500DC |
||
| (*1) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor. (*2) The stated battery life is for when it is used in an environment of 25°C and recorded data is downloaded at a rate of once a day or "Monitoring Current Readings" occurs at a rate of once every 10 minutes. Battery life depends on measurement environment, recording interval and battery performance. (*3)The same amount of time will be necessary for each added Repeater. (*4) The stated water resistance rating is for when the sensor is connected to the unit. However, this does not include the sensor areas for the RTR-503/503L models. Not for continued immersion. |
|||
| FCC model / CE model | RTR-505-TC/ 505-TCL |
RTR-505-Pt/ 505-PtL |
RTR-505-V/ 505-VL |
RTR-505-mA/ 505-mAL |
RTR-505-P/ 505-PL |
|---|---|---|---|---|---|
| Measurement Items (*1) | Temperature | Voltage | 4-20mA | Pulse | |
| Recording Intervals | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. / 1, 2, 5, 10, 15, 20, 30, 60 min. | ||||
| Logging Capacity | 16,000 readings | ||||
| Recording Modes | Endless: Upon reaching logging capacity, the oldest data is overwritten and recording continues. One Time: Recording automatically stops when logging capacity is full. * When using RTR-500NW or RTR-500AW as a Base Unit, only "Endless" can be selected. |
||||
| LCD Displayed Items | Measurement, Recording Status, Recording Mode, Battery Life Warning, Unit of Measurement, Full (Logging Capacity FULL), Sensor Unconnected, Input Module Unconnected, Measurement Range Exceeded, Display Range Exceeded) | ||||
| Power | Lithium Battery LS14250 (*2) x 1 / Lithium Battery CR2 x 1 For L type: Large Capacity Battery Adaptor Kit (RTR-500B1 /sold separately) External Power Adaptor Kit (RTR-500A1 /sold separately) |
||||
| Battery Life (*3) | About 10 months (for temperature measurement) About 4 years (for temperature measurement with L type) |
||||
| Radio Standard Specifications | FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz) ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz) |
||||
| Wireless Transmission Range | About 150 meters (500ft) if direct and unobstructed | ||||
| Communication Interfaces | Wireless Communication / Optical Communication | ||||
| Communication Time | When downloading one Remote Unit at full logging capacity Wireless Communication: about 2 min. Optical Communication: about 160 sec. |
||||
| Waterproof Capacity | Splash proof (rated for use in daily life) (*4) | ||||
| Dimensions | H62mm x W 47mm x D19mm (excluding protrusions and sensor) L type: D 46.5mm (with Large Capacity Battery Pack) Antenna length: 24mm |
||||
| Weight | About 55g (including battery / excluding Input Module) L Type: about 109g (with Large Capacity Battery Pack) |
||||
| Operating Environment | - 30 to 80°C (*5) (The operating temperature range and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C.) |
||||
| Other | In order to download data via wireless communication, it is necessary to purchase Base Unit: RTR-500, RTR-500NW/500AW or RTR-500DC |
||||
| (*1) For information about measurement range, see the specifications of each Input Module in the Options Page. (*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set for low-temperature use (TR-11P2) for replacement. (*3) Battery life varies depending upon the connected Input Module, measuring environment, frequency of communication, Unit settings, and battery performance. (*4) This is the waterproof capacity of a Unit with an Input Module connected. Note that sensor connector of the Input Module is not water resistant. (*5) If you are using a Data Logger in an environment where temperatures may be lower than -20°C or higher than 60°C, we strongly suggest purchasing and using the optional battery set for low-temperature use (TR-11P2) |
|||||
| Product | RTR-574 | RTR-574-H | ||
|---|---|---|---|---|
| Temperature/Humidity Sensor (External) | THA-3151 | HHA-3151(High-Precision Type) | ||
| Thermistor | Polymer Resistance | Platinum Resistance | Electrostatic Capacitance | |
| Measurement Channels | Temperature 1ch | Humidity 1ch | Temperature 1ch | Humidity 1ch |
| Units of Measurement | °C, °F | %RH | °C, °F | %RH |
| Measurement Range | 0 to 55 °C | 10 to 95 %RH | -30 to 80 °C | 0 to 99 %RH |
| Accuracy | ±0.5 °C | ±5 %RH (at 25 °C, 50 %RH) | ±0.3°C (at 10 to 40 °C) ±0.5°C (at all other temperatures) | ±2.5 %RH(at 25 °C, 10 to 85 %RH) ±4.0 %RH(at 25 °C, 0 to 10 % or 85 to 99 %RH) At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*1) |
| Measurement Resolution | 0.1 °C | 1 %RH | 0.1 °C | 0.1 %RH |
| Response Time (90%) | Approx. 7 min. | Approx. 7 min. | Approx. 20 sec. | |
| Illuminance/UV Sensor (External) | ISA-3151 | |||
| Measurement Channels | Illuminance: 1ch UV intensity: 1ch |
|||
| Units of Measurement | Illuminance: lx, Klx UV intensity: mW/cm2 |
|||
| Measurement Range | Illuminance: 0 lx to 130 Klx UV Intensity: 0 to 30 mW/cm2 |
|||
| Units of Cumulative Measurement | Cumulative Illuminance: lxh, Klxh, Mlxh Cumulative amount of UV Light: mW/cm2, W/cm2 |
|||
| Display Range of Cumulative Measurement |
Illuminance: 0 lxh to 90 Mlxh UV Intensity: 0 mW to 62 W/cm2h |
|||
| Accuracy | Illuminance: 10 lx to 100 Klx:±5 % (at 25°C, 50 %RH) UV Intensity: 0.1 to 30 mW/cm2:±5 % (at 25°C, 50 %RH) (*2) | |||
| Relative Spectral Response | Illuminance: Approximated to the CIE standard response function V (λ ) UV Intensity: 260 to 400 nm |
|||
| Measurement Resolution | Illuminance: Minimum of 0.01 lx UV Intensity: Minimum of 0.001 mW/cm2 |
|||
| Response Time (90%) | 3 sec. (at recording interval of 1 sec.) 6 sec. (at other intervals) |
|||
| Logging Capacity | 8,000 data sets (One data set consists of readings for all channels in that type of unit.) | |||
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |||
| Recording Mode (*3) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) | |||
| LCD Display Items | Measurements, Battery Life Warning, etc. - Measurements: Illuminance / UV Intensity / Temperature / Humidity / Cumulative Illuminance / Cumulative amount of UV Light - Display Pattern: Alternating or Fixed display - Display Digits: Up to 4 digits |
|||
| Communication Interfaces |
- Wireless Communication (Short Range Radio Communication) FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW) ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) - USB Communication - Serial Communication (RS-232C) (*4) |
|||
| Wireless Transmission Range | Approx. 150 meters (500 ft) if direct and unobstructed | |||
| Power | AA Alkaline Battery (LR6) x 1 | |||
| Battery Life (*5) | Approx. 4 months | |||
| Dimensions | H 55 mm x W 78 mm x D 18 mm(excluding protrusions) Antenna Length: 60 mm |
|||
| Weight | About 68 g (including battery, excluding sensor) | |||
| Operating Environment | Temperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation) | |||
| Accessories | AA alkaline battery (LR6), USB Communication Cable (US-15C), Illuminance/UV Sensor (ISA-3151), Temperature/Humidity Sensor (THA-3151 or HHA-3151), Software (CD-ROM), User's Manual Set (Warranty Included) | |||
| Compatible Base Units | RTR-500C, RTR-500NW/500AW, RTR-500DC | |||
|
||||