RTR-500GSM for Windows
Overview
RTR-500GSM for Windows is the exclusive software for carrying out settings and managing data for the RTR-500GSM. It includes the following three applications: RTR-500GSM Settings Utility , Temperature/ Humidity Graph, and Adjustment Tools.
For details about how to use the software applications, see the Operation Guide within that application.
For details about how to use the software applications, see the Operation Guide within that application.

Compatible devices
DataLoggers
- RTR-500 Series
Communication & Collection
- RTR-500GSM (Base Unit)
- RTR-500 (Repeater)
Function
- RTR-500GSM Settings Utility
- Temperature / Humidity Graph
- Adjustment Tools
- Easy-to-Understand Operation Guide
RTR-500GSM Settings Utility
This is the main application for RTR-500GSM for Windows. It is used to make Base Unit settings, register Remote and Repeater Units, make Auto-Download settings and Warning Report settings.


When using the RTR-500GSM, we have included an "Initial Settings Wizard" which guides you through what otherwise would be difficult process of setting up the unit for GSM network communication, just put in the SIM Card and turn on the Wizard.
Temperature / Humidity Graph
This application enables the viewing and processing of downloaded data. It is possible to view the downloaded data in graph and table form, as well as print or convert into text file data.

Display Data in Table Form
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.

Adjustment Tools
If data logger measurements are compared to measurements of a device that serves as a standard and small inaccuracies are found to occur in the data logger readings, it is possible in the “Adjustment Tools” application to correct for these inaccuracies by making adjustment settings so that data logger readings and recorded data reflect the measurements of the device serving as the standard. To make settings simply select the adjustment method from either “1 Point Adjustment” or “2 Point Adjustment” and enter values for “Before Adjustment” and “After Adjustment” .
(The Settings Window may differ slightly depending on the software being used)
(The Settings Window may differ slightly depending on the software being used)

Easy-to-Understand Operation Guide
The Operation Guide that is part of the software uses easy to understand terms to help lead you through all the necessary steps and setting procedures. If during setup you get confused or have trouble, just simply open the Operation Guide in the same on-screen window and proceed while consulting the guide.
Specifications
| Software Information | |
|---|---|
| Compatible Devices | Base Unit: RTR-500GSM Remote Unit: RTR-501/501L, RTR-502/502L, RTR-503/503L Repeater Unit: RTR-500 |
| Compatible OS (*1) | RTR-500GSM for Windows(US) Microsoft Windows 7 32/64bit English, Spanish Microsoft Windows Vista 32bit English, Spanish Microsoft Windows XP 32bit(SP2 or above) English, Spanish RTR-500GSM for Windows(EU) Microsoft Windows 7 32/64bit English, Spanish, French, German, Italian Microsoft Windows Vista 32bit English, Spanish, French, German, Italian Microsoft Windows XP 32bit(SP2 or above) English, Spanish, French, German, Italian |
| Display Languages | English, Spanish, French, German, Italian |
| PC/CPU | A Stable Windows Operating Environment |
| Memory | A Stable Windows Operating Environment |
| Disk | More than 30MB of free space (Data will need more space) |
| Monitor | SVGA(800x600) more than 256 colors |
| (*1) For installation, it is necessary to have Administrator (Computer Administrator) rights. | |
| RTR-500GSM Settings Utility | |
|---|---|
| Initial Settings | PIN Number Settings, Access Point Settings(Access Point Name/User ID/Password), Transmission Tests |
| Base Unit Settings | Base Unit Settings, Unit of Temperature, Control via SMS, PIN Authentication, GPRS Settings |
| Remote Unit Registration/Settings |
Group Name, Remote Unit Name, Remote Unit Number, Serial Number, Communication Frequency Channel, Recording Interval Warning Settings (Warning Judgement Time, Upper/Lower Limit, Enable Auto-Download) |
| Repeater Unit Registration/Settings |
Group Name, Repeater Number, Serial Number, Communication Frequency Channel |
| Base Unit Operational Settings |
Wireless Route Settings, Clock Settings, E-mail Settings, FTP Settings Send Current Readings Settings, Warning Report Settings Auto-Download Settings, Transmission Tests |
| Temp/Humidity Graph | |
| Graph: | Temp/Humidity Graphs for Each Channel (Zoom out/in and scroll), Change Channel Colors, Turn ON and OFF Channel Display |
| Data Display: | Channel Name, Recording Interval, Number of Readings, Highest / Lowest and Average Reading, Unit of Measurement, AB Cursor Dates, Times and Data Readings, Calculated Difference between Cursor A and B |
| Screen Display Data |
Channel Name / Recording Interval / Number of Readings Highest, Lowest and Average Reading / Unit of Measurement AB Cursor Dates / Times and Data Readings Calculated Difference between Cursor A and B |
| Number of Channels: | 8 Channel Simultaneous Display and Processing |
| Others | Data List Display, Calculation Range Settings, Data Maintenance, Edit Recording Conditions, Delete Data by Channel, Re-order Data by Channel |
| File Output | Common Data Files (*.trx) / Text File (CSV, etc), Selected Range: (File for selected time period) |
| Printing | Graphs / Tables |
| Adjustment Tools | |
| Adjustment Channels | Ch.1: Temperature / Ch.2: Humidity |
| Method | 1 point Adjustment: Use when measuring in a range of +/-20°C 2 point Adjustment: Use when measuring in a wide range. |