RTR-500W for Windows
Overview
RTR-500W for Windows is the exclusive software for carrying out settings and managing data for the RTR-500W. It includes the following five applications: RTR-500W Settings Utility, Temperature/ Humidity Graph, Multi-Scale Graph, Adjustment Tools, and Download Data Tool.
For details about how to use the software applications, see the Operation Guide within that application.
For details about how to use the software applications, see the Operation Guide within that application.

Compatible devices
DataLoggers
- RTR-500 Series (Remote Unit)
Communication & Collection
- RTR-500NW/500AW (Base Unit)
- RTR-500 (Repeater)
Function
- RTR-500W Settings Utility
- Temperature / Humidity Graph
- Multi-Scale Graph
- Easy-to-Understand Operation Guide
RTR-500W Settings Utility
The RTR-500W Settings Utility is an application to make settings for the operation of the Base Unit (RTR-500NW/500AW) and the registration of Remote Units and Repeaters.
The Settings Utility application is designed to allow the User to easily understand all of the necessary settings items for the Base Unit and smoothly carry out all types of settings from Network Settings to Settings for Automatically Sending Recorded Data and Warning Reports.
The Settings Utility application is designed to allow the User to easily understand all of the necessary settings items for the Base Unit and smoothly carry out all types of settings from Network Settings to Settings for Automatically Sending Recorded Data and Warning Reports.

Temperature / Humidity Graph
In this display you can view in graph form the data measured and recorded by the RTR-501 / 502 / 503.
Up to eight channels of temperature and humidity data can be simultaneosly viewed in one Temp / Humidity Graph and up to eight channels of voltage, pulse, temperature and humidity data can be view channels, make changes to graph colors and zoom-in and -out on data with the click of a mouse. Color printing of the graph, as you see it on display, is also possible.
Up to eight channels of temperature and humidity data can be simultaneosly viewed in one Temp / Humidity Graph and up to eight channels of voltage, pulse, temperature and humidity data can be view channels, make changes to graph colors and zoom-in and -out on data with the click of a mouse. Color printing of the graph, as you see it on display, is also possible.

Display Data in Table Form
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.

Multi-Scale Graph
The recorded data (up to two units of data) from an RTR-574 can be easily viewed in one Multi-Scale Graph.
It is possible to hide/view the vertical axis scales, scroll the vertical axis scales and make range display settings for each channel.
By moving the two cursors (A and B) to points on the graph it is possible to view the recorded value for those particular points and calculate the difference in the values at those specific points. It is also possible to calculate and view the highest, lowest and average readings for a desired range (time period).
It is possible to hide/view the vertical axis scales, scroll the vertical axis scales and make range display settings for each channel.
By moving the two cursors (A and B) to points on the graph it is possible to view the recorded value for those particular points and calculate the difference in the values at those specific points. It is also possible to calculate and view the highest, lowest and average readings for a desired range (time period).

Display Data in Table Form
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.

Easy-to-Understand Operation Guide
The Operation Guide that is part of the software uses easy to understand terms to help lead you through all the necessary steps and setting procedures. If during setup you get confused or have trouble, just simply open the Operation Guide in the same on-screen window and proceed while consulting the guide.
Specifications
| Software Information | |
|---|---|
| Compatible Devices | Base Unit: RTR-500NW, RTR-500AW Remote Unit: RTR-501/501L, RTR-502/502L, RTR-503/503L, RTR-574 Repeater Unit: RTR-500 |
| Compatible OS (*1) | Microsoft Windows 7 32/64bit English, Spanish, French, German, Italian Microsoft Windows Vista 32bit English, Spanish, French, German, Italian Microsoft Windows XP 32bit(SP2 or above) English, Spanish, French, German, Italian |
| Display Languages | English, Spanish, French, German, Italian |
| PC/CPU | A Stable Windows Operating Environment |
| Memory | A Stable Windows Operating Environment |
| Disk | More than 30MB of free space (Data will need more space) |
| Monitor | SVGA(800x600) more than 256 colors |
| (*1) For installation, it is necessary to have Administrator (Computer Administrator) rights. | |
| RTR-500W Settings Utility | |
|---|---|
| Base Unit Settings | Base Unit Name, Unit of Temperature, Base Unit Description and LAN Password |
| Remote Unit Registration/Settings |
Group Name, Remote Unit Name, Remote Unit Number, Communication Frequency Channel, Recording Interval, Warning Monitoring, Warning Judgement Time, Upper and Lower Limits, Auto-Downloading and Sending of Recorded Data, Channels for Alternating Display (RTR-574), Button Lock (RTR-574) |
| Repeater Unit Registration/Settings |
Serial Number, Group Name, Repeater Number, Communication Frequency Channel |
| Base Unit Operational Settings |
Wireless Route Settings, Clock Settings, Network Settings, E-Mail Settings, FTP Settings, Settings for Sending Current Readings, Warning Report Settings, and Settings for Sending Recorded Data, Transmission Tests |
| Temp/Humidity Graph | |
| Graph: | Temp/Humidity Graphs for Each Channel (Zoom out/in and scroll), Change Channel Colors, Turn ON and OFF Channel Display |
| Data Display: | Channel Name, Recording Interval, Number of Readings, Highest / Lowest and Average Reading, Unit of Measurement, AB Cursor Dates, Times and Data Readings, Calculated Difference between Cursor A and B |
| Screen Display Data |
Channel Name / Recording Interval / Number of Readings Highest, Lowest and Average Reading / Unit of Measurement AB Cursor Dates / Times and Data Readings Calculated Difference between Cursor A and B |
| Number of Channels: | 8 Channel Simultaneous Display and Processing |
| Others | Data List Display, Calculation Range Settings, Data Maintenance, Edit Recording Conditions, Delete Data by Channel, Re-order Data by Channel |
| File Output | Common Data Files (*.trx) / Text File (CSV, etc), Selected Range: (File for selected time period) |
| Printing | Graphs / Tables | Multi-Scale Graph |
| Number of Channels | 8 Channnels |
| Graph | Illuminance / UV Light / Temperature / Humidity Graphs for each Channel, (Zoom in/out and scroll with mouse or keyboard), Change Display Colors for Channels, View / Hide for Channels, Delete Data by Channel, Re-order Data by Channel, Vertical Axis Settings, Data List Display, Calculation Range (Time Period) Settings |
| File Output | Special T&D Data File / Text File(CSV, etc) (Select Range of Data or Entire File for output.) |
| Printing | Graphs / Tables |
| Others | Start / Cancel Downloading |