RTR-5W for Windows
Overview
The [RTR-5W for Windows] software has been designed to allow for the carrying out of various tasks such as network settings, downloading of recorded data and graph display of recorded data, as well as the management of Groups of Remote Units.
[RTR-5W for Windows] is made up of 5 applications, complete with our Auto-Download feature that allows for the downloading of logged data at either a set interval or at a set time of day. [RTR-5W for Windows] (the main software) allows for the basic management of Groups of Remote Units, the monitoring of current readings and the settings for Remote Units. The [Network Settings Utility] facilitates the setting up of a network. With [Temperature・Humidity Graph], you can view downloaded recorded data in graph form. Also included are [Multi-Scale Graph], our multi-channel data viewing software and [Event Viewer], which permits for the display of logged pulse and event data and the easy printing of graphs as displayed.
After installation has been completed, [RTR-5W for Windows], [Event Viewer], [Network Setting Utility], [Multi-Scale Graph] and [Temperature・Humidity Graph] will be registered in the Window's <Start> Menu. Open by clicking on the application you wish to use.
[RTR-5W for Windows] has four main basic functions.
[RTR-5W for Windows] is made up of 5 applications, complete with our Auto-Download feature that allows for the downloading of logged data at either a set interval or at a set time of day. [RTR-5W for Windows] (the main software) allows for the basic management of Groups of Remote Units, the monitoring of current readings and the settings for Remote Units. The [Network Settings Utility] facilitates the setting up of a network. With [Temperature・Humidity Graph], you can view downloaded recorded data in graph form. Also included are [Multi-Scale Graph], our multi-channel data viewing software and [Event Viewer], which permits for the display of logged pulse and event data and the easy printing of graphs as displayed.
After installation has been completed, [RTR-5W for Windows], [Event Viewer], [Network Setting Utility], [Multi-Scale Graph] and [Temperature・Humidity Graph] will be registered in the Window's <Start> Menu. Open by clicking on the application you wish to use.
[RTR-5W for Windows] has four main basic functions.
Making Settings for the Controlling of an RTR-5W by PC over a network.
Via a network, it is possible to make not only network settings in the RTR-5W, but also recording condition settings and warning settings as well. Even, if there are more than one RTR-5W connected to the network, it is easy to make settings by viewing the list in the Network Settings Utility and make all necessary settings.
Register and Make Settings for Remote Units as well as Divide Remotes into Groups.
RTR-5W for Windows allows you to register any logger in the RTR-5 Series as a Remote Unit and carry out settings for that Remote.
Also, if more than one Remote Unit has been registered, the unit s can be divided into Groups for easy management.
Also, if more than one Remote Unit has been registered, the unit s can be divided into Groups for easy management.
Interpret Data in Graphs and Tables
Recorded data can be displayed in colorful easy to interpret graphs and tables and analyzed by using [Temperature /Humidity Graph] and [Multi-Scale Graph]. Full use of the Windows interface makes the operation simple yet dramatic.
Export Data to be Saved or Printed
Recorded data can be easily saved into files or exported for printing. It is possible to convert the data for a specified range (time period) to common text file format, so that it can be exported to spreadsheet software such as Excel or Lotus.
Compatible devices
Communication & Collection
- RTR-5W
Function
RTR-5W for Windows
RTR-5W for Windows is designed to allow the user to carry out various tasks such as: Remote Unit Registration, Group Registration, Warning Monitoring Settings, as well as the making Settings for the Gathering of Current Readings.

Remote Registration / Group Settings
Register loggers in the RTR-5 Series as Remote Units and register into Groups
Recording Start/Stop Settings
Make settings to start and stop recording in registered Remote Unit(s).
Register loggers in the RTR-5 Series as Remote Units and register into Groups
Recording Start/Stop Settings
Make settings to start and stop recording in registered Remote Unit(s).

Warning Monitoring Settings
Monitoring at each location for warnings is carried out and if any of the gathered data exceeds the set limit, a notification can be sent via e-mail. Here it is possible to make settings for the recipient address for the warning mail and for the settings to turn ON or OFF the Contact External Output function.
Downloading Recorded Data
Download recorded data via a network from any registered Remote Unit.
Gathering Current Readings
Gather current measurement readings from any registered Remote Unit.
Auto-Download Settings
The downloading of data can be set to be aut
Monitoring at each location for warnings is carried out and if any of the gathered data exceeds the set limit, a notification can be sent via e-mail. Here it is possible to make settings for the recipient address for the warning mail and for the settings to turn ON or OFF the Contact External Output function.
Downloading Recorded Data
Download recorded data via a network from any registered Remote Unit.
Gathering Current Readings
Gather current measurement readings from any registered Remote Unit.
Auto-Download Settings
The downloading of data can be set to be aut
Network Settings Utility
The Network Settings Utility contains operational settings for such functions as Network Initialization Settings 、Warning Report Settings、Gather Current Reading Settings and others.
NOTE:
If you open the Network Settings Utility on multiple computers in the same network, it may not work properly. Please open the Network Settings Utility from only one computer at a time in the same network (same broadcast domain).
If you open the Network Settings Utility on multiple computers in the same network, it may not work properly. Please open the Network Settings Utility from only one computer at a time in the same network (same broadcast domain).
Network Initialization Settings
Set for helping to connect a RTR-5W to a network.
RTR-5W Detailed Network Settings
Make detailed network settings here.
Set for helping to connect a RTR-5W to a network.
RTR-5W Detailed Network Settings
Make detailed network settings here.

Temperature/Humidity Graph
This exclusive software application was designed for use with the RTR-5 Series to help manage data, including the display of recorded temperature and humidity data in graph form. This software is also compatible with recorded data from TR-7S/TR-7U/TR-7W/RTR/RPR-7 and with it their data files can also be read and viewed.
Graph Display
It is possible to simultaneously view 8 channels of data. It is also possible to hide, re-order and delete channels when necessary. Moreover, data recording start times and graph display colors can be changed as desired.
By moving the two cursors to points on the graph it is possible to view the recorded value for those particular points and calculate the difference in the values at those specific points.
Calculate and view the highest, lowest and average readings for a desired range.
Viewing Downloaded Data
The [Temp / Humidity Graph] program will read data files that have been created from the downloaded data from the loggers and to help you analyze that data will allow you to create graphs, data lists, text files, and print data.
View Recorded Data List
You can view all the recorded data including its time and date as a list. In the data list, the highest, lowest and average readings for a specified range (time period) will appear, distinguished by different colors. This window is different from a standard dialog box, in that you can change the size and scroll the list up / down or left / right.
Graph Display
It is possible to simultaneously view 8 channels of data. It is also possible to hide, re-order and delete channels when necessary. Moreover, data recording start times and graph display colors can be changed as desired.
By moving the two cursors to points on the graph it is possible to view the recorded value for those particular points and calculate the difference in the values at those specific points.
Calculate and view the highest, lowest and average readings for a desired range.
Viewing Downloaded Data
The [Temp / Humidity Graph] program will read data files that have been created from the downloaded data from the loggers and to help you analyze that data will allow you to create graphs, data lists, text files, and print data.
View Recorded Data List
You can view all the recorded data including its time and date as a list. In the data list, the highest, lowest and average readings for a specified range (time period) will appear, distinguished by different colors. This window is different from a standard dialog box, in that you can change the size and scroll the list up / down or left / right.

Graph & Data List Printing
By clicking, the List Print Preview Dialog Box will appear. The Print Preview Display will take the place of the Main Window and the image of what will be printed will be displayed. By using the Print Preview Display Toolbar you can carry out various operations such as enlarge or reduce the display as desired, and start printing.
By clicking, the List Print Preview Dialog Box will appear. The Print Preview Display will take the place of the Main Window and the image of what will be printed will be displayed. By using the Print Preview Display Toolbar you can carry out various operations such as enlarge or reduce the display as desired, and start printing.
Specifications
| RTR-5W for windows | |
|---|---|
| Compatible Devices | RTR-5 / RVR-5 Series Data Loggers |
| Functions | Remote Unit Registration, Download Data, Auto-Download Settings, Warning Report Settings, Gather Current Readings |
| Network Settings Utility | |
|---|---|
| Compatible Devices | RTR-5W |
| Functions | Network Initialization Settings, Detailed Network Settings, Warning Report Settings, Adjustment, Gather Current Readings Settings |
| Temperature/Humidity Graph | |
|---|---|
| Compatible Devices | RTR-5W, TR-7,TR-5 Series and RTR-7,RTR-5 Series |
| Number of Channels | 8 Channels Simultaneous Display / Processing, Download Recorded Data |
| Graph Display, Temp / Humidity Graph | Temperature / Humidity Graphs for each Channel(Zoom in/out and scroll with mouse or keyboard) Change Display Colors for Channels, View/ Hide Channels Simultaneous Display / Processing, Download Recorded Data |
| Data | Channel Name, Recording Interval, Number of Readings, Highest, Lowest and Average Readings, Unit of Measurement.AB Cursor Dates/Times and Temp / Humidity Readings Calculated Temp / Humidity Difference between Cursor A and B |
| File Output | Special T&D Data File, Text File(CSV, etc) (Output Selected Range of Data or Entire File) |
| Printing | Graphs / Tables |
| Others | Data List Display, Calculation Range (Time Period) Settings, Data Maintenance, Delete Data by Channel, Re-order Data by Channel, Vertical Scale Settings |
| Compatible | |
|---|---|
| Compatible OS | Microsoft Windows 7 32/64bit English Microsoft Windows Vista 32bit English Microsoft Windows XP 32bit(SP2 or above) English Microsoft Windows 2000 English (*1) |
| Display Languages | English |
| PC/CPU | A Stable Windows Operating Environment LAN・TCP/IP Communication Possible |
| Memory | Enough memory to stably operate Windows |
| Hard Disk | More than 10MB free space(More free space is necessary for data) |
| Monitor | Recommend SVGA(800x600)or higher/more than 256 colors |
| LAN | 100BASE-TX or 10BASE-T Twisted pair cable confirming to Category 5(STP/UTP) |
| Web Browser | Internet Explorer 6.0 or higher |
| (*1) To install the [Network Settings Utility], it may be necessary to have Administrator Rights for the computer into which it will be installed. | |