T&D Recorder for Windows (RTR-5)
Overview
T&D Recorder for Windows (RTR-5) has been designed as a user friendly tool allowing users total control over the management of any T&D data logger including controlling all relevant settings, data gathering and processing, as well as, all display and printing functions.
T&D Recorder for Windows (RTR-5) is made up of separate independent applications or "modules" for each type of data logger and graph. (Each is an independent application.)
T&D Recorder for Windows (RTR-5) is made up of separate independent applications or "modules" for each type of data logger and graph. (Each is an independent application.)
About the Launcher
Upon opening T&D Recorder for Windows (RTR-5), the launcher will appear as a set of icons. By clicking on an icon, the graph and / or communication displays for that type of unit will appear.

For each icon, it is possible to change the settings to hide or show that icon, making it possible to hide unnecessary icons.
It is also possible to display the icons in the main window in a smaller reduced size.
It is also possible to display the icons in the main window in a smaller reduced size.
When in reduced size, besides clicking on an icon to open a graph or a communication display for that type of unit, right clicking will open a menu. It is also possible to move the icons by dragging the launcher to a different place on the screen.
Compatible devices
DataLoggers
- RTR-5 Series
- RTR-57C
- RTR-57U
Function
- Up to 8 Channnels of Data in One Graph
- Data Collection
- Display Data in Table Form
- Save as Text File Function
Up to 8 Channnels of Data in One Graph
Up to eight channels of temperature and humidity data can be simultaneosly viewed in one Temp / Humidity Graph and up to eight channels of voltage, pulse, temperature and humidity data can be view channels, make changes to graph colors and zoom-in and -out on data with the click of a mouse. Color printing of the graph, as you see it on display, is also possible.

Data Collection
Upon downloading, a data collection report is displayed in an easy-to-view list. From there it is possible to change all downloaded data or selected data into graph form or into Text File Format.
To specify data file(s), while holding down the [Ctrl] button or the [Shift] button click on the files you wish to download in the collected data list.
To specify data file(s), while holding down the [Ctrl] button or the [Shift] button click on the files you wish to download in the collected data list.
Display Data in Table Form
The data in the graph can be viewed in table form with the High in red, the Low in blue and the Average in pink. You can print all of the data in the list or select and print only those pages you desire.

Save as Text File Function
This function allows you to save data in Text File Format (CSV Format); in order to use the data with spreadsheet applications such as Excel and Lotus.
Specifications
| T&D Recorder for Windows (RTR-5) | |
|---|---|
| Compatible Devices | RTR-57C, RTR-57U, RTR-51/51A/52/52A/52Pt/53/53A, RVR-52/52A |
| Number of Channels | 8 Channel Simultaneous Display and Processing (Up to 4 RTR-53/53A units / Up to 8 units for RTR-51/51A/52/52A/52Pt and RVR-52/52A Possible to process mixed data from TR-5 and TR-7 series units) |
| Communication Functions | |
| RTR-5(RTR-5A) | Recording Start (Immediate Start / Programmed Start), Recording Stop / Main Unit Settings (Recording Interval / Recording Method / Upper and Lower Limits / Permission to Start Recording by Wireless Communication) / Downloading of Recorded Data / (Adjustment) |
| RVR-5(RVR-5A) | Recording Start (Immediate Start / Programmed Start) / Recording Stop / Main Unit Settings [Recording Method, Upper and Lower Limits, Voltage Measurement Method (Instantaneous Value / Average Value), Pulse Measurement Method (Rising Lo-Hi, Falling Hi-Lo) Permission to start Recording by Wireless Communication] Downloading of Recorded Data / (Adjustment / Moisture Adjustment) |
| RTR-57C/57U | Remote Unit and/or Group Settings and Contents Display / Communication Frequency / Channel Settings / Collect Data Info / Data Info Display / Delete Data / Download Data / Set Clock / Upper and Lower Limit Settings |
| Temp / Humidity Graph | |
| Graph Display | Temp / Humidity Graphs for each Channel (Zoom in / out and scroll) Change Channel Colors / Turn ON and OFF Channel Display |
| Data Display | Channel Name / Recording Interval / Number of Readings Highest, Lowest and Average Reading / Unit of Measurement AB Cursor Dates / Times and Data Readings Calculated Difference between Cursor A and B |
| File Output | T&D Specific File Output / Text File (CSV,etc..) (Possible to select specific range for output) |
| Printing | Prining Graphs / Tables |
| Others | Data List Display / Calculation Range Settings / Data Maintenance / Edit Recording Conditions / Delete Data by Channel / Re-order Data by Channel |
| Multi-scale Graph | |
| Graph Display | Graphs for Each Channel (Zoom in/out and scroll with mouse or keyboard), Vertically Scroll Graph for Each Channel, Channel Graph Color, Background Color, Customize Graph Scale Lines, Turn ON and OFF Channel Display, Move Vertical Scale to Desired Position in Graph (View / Hide Scale for Each Channel) |
| Data Display | Channel Name, Recording Interval, Number of Readings, Highest,/ Lowest and Average Reading, Unit of Measurement, AB Cursor Dates / Times and Data Readings, Calculated Difference |
| Others | Data List Display, Change Scales, Calculation Range Settings, Set Display Range for Vertical Axis |
| Event Viewer | |
| Event List | Edit Recording Conditions, Delete Data by Channel, Re-order Data by Channel, Event List Display showing Time of Event for Each Channel (possible to scroll with mouse or keyboard), Rising Signal (Lo -> Hi) / Falling Signal (Hi -> Lo) / Falling Signal & Rising Signal, Hide or View Other Functions, Ascending -Descending Order Switch |
| File OutPut | T&D Common Data File, Text File (CSV/ etc), (Selected Range or File for Entire Period) |
| Printing | Graphs / Tables |
| Others | Serial Port Auto Find Function |
| Compatible | |
| Compatible OS (*1) | Microsoft Windows 7 32/64bit English Microsoft Windows Vista 32bit English Microsoft Windows XP 32bit(SP2 or above) English |
| Display Languages | English |
| PC / CPU | A Stable Windows Operating Environment Serial Port (RS232-C D-sub 9pin) |
| Memory | A Stable Windows Operating Environment |
| Hard Disk | More than 40MB of free space (Data will need more space) |
| Monitor | VGA (640 x 480) more than 256 colors |