Voltage Recorder for Windows
Overview
Voltage Recorder for Windows is software specially designed to be used with our VR-71 data logger that measures, records and displays voltage. By connecting a VR-71 to the communication port of your computer the software allows you to download recorded data, start and stop recording sessions, make recording condition and other important logger settings
Data that has been downloaded from the logger can be easily displayed in graph form, saved to files, or exported as text file data.
Data that has been downloaded from the logger can be easily displayed in graph form, saved to files, or exported as text file data.
The Structure of the System
The system is made up of a VR-71 logger (the unit that records voltage from the sensor), the software (Voltage Recorder for Windows) and the communication cable.
Compatible devices
DataLoggers
- VR-71
Function
- Up to 8 Channels of Data can be Processed at One Time
- Creating Text Files
- Graph / Table Printing Function
- Programmed Recording Start Function / Scale and Unit Conversion Function
Up to 8 Channels of Data can be Processed at One Time
By simply downloading the data from the main unit a colorful graph representing that data will be automatically created. Up to 8 channels(4 unitss of data can be represented in one graph.
The data scale and unit to be used in the display can be set with the scale settings.
The data scale and unit to be used in the display can be set with the scale settings.
Multi-scale Graph
By using the mouse to drag and draw a box you can easily zoom in on desired data. You can also use the menu or the keyboard to zoom in and out on data.
By using the mouse to drag and draw a box you can easily zoom in on desired data. You can also use the menu or the keyboard to zoom in and out on data.

・By moving the cursors on to a specific date and time you can easily view recorded data as well as the calculated differences between date A and B.
・By selecting a calculation range you can have displayed the High, Low and Average readings for that chosen period.
・By selecting a calculation range you can have displayed the High, Low and Average readings for that chosen period.
Creating Text Files
You can create Text Files (CSV format, etc...) to allow you the option of processing and managing your data using Excel, Lotus or any other popular spreadsheet software.
Graph / Table Printing Function
You can print out in color or monochrome the graphs just as they appear on your screen. You can also print out in table form all of the data in order of date and time.
Programmed Recording Start Function / Scale and Unit Conversion Function
By setting a date and time in the main unit you can easily program to start recording on that date at the set time. In the Scale Settings you can set the unit of measurement and the values for the scale and these settings will be reflected in the LCD on the logger and in Graphs. It is also possible to edit and create the unit of measurement for display in the logger LCD.

Specifications
| Voltage Recorder for Windows(E) | |
|---|---|
| Compatible Devices | VR-71 |
| Number of Channels | 8 Channnels Simulaneous Display and Processing Possible to process a mixture of up to 4 VR-71 units |
| Communication Functions | Recording Start (Programmed Start / Immediate Start), Recording Stop, Main Unit Settings (Channel Name / Recording Interval / Recording Method / Upper and Lower Limits / Expansion Unit Settings), Downloading of Recorded Data, Create display unit and transmit to logger (dot matrix pattern), Voltage input conversion equation (2-point or y=Ax+B) setup and transmission to logger, Auto detect of Serial COM Port |
| Graph Display | Graphs for each Channel (Zoom in / out and scroll with mouse or keyboard), Vertically Scroll Graph for Each Channel, Channel Graph Color/ Background Color, Customize Graph Scale Lines, Turn ON and OFF Channel Display, Move Vertical Scale to Desired Position in Graph (View/ Hide Scale For Each Channel), Display Current Data in Trend Graph ( no saving to file) |
| Data Display | Channel Name, Recording Interval, Number of Readings Highest, Lowest and Average Readings, Unit of Measurement AB Cursor Dates / Times and Data Readings・Calculated Difference between Cursor A and B |
| File Output | Voltage Recorder Data File / Text File (CSV, etc)(Selected Range or File for Entire Period) |
| Printing | Graph / Tables |
| Others | Data List Display, Change Scales, Calculation Range Settings Set Display Range for Vertical Axis, Edit Recording Conditions・Delete Data by Channel, Re-order Data by Channel |
| Compatible OS | Microsoft Windows 7 32/64bit English Microsoft Windows Vista 32bit English Microsoft Windows XP 32bit (SP2 or above) English Microsoft Windows 2000 English Microsoft Windows Me English Microsoft Windows 98SE English |
| Display Languages | English |
| PC/CPU | A Stable Windows Operating Environment Serial Port (RS232-C D-sub 9pin) |
| Memory | A Stable Windows Operating Environment |
| Hard Disk | More than 20MB of free space (Data will need more space) |
| Monitor | Recommend VGA / SVGA (800 x 600) or higher / more than 256 colors |