TR-5 Series - Compact Waterproof Temperature Data Logger

Specifications
  TR-51A TR-52
Measurement Channel 1 Ch (Temperature) 1 Ch (Temperature)
Internal Sensor -40 to 80°C -
External Sensor - -60 to 155°C
Measurement Accuracy ±0.5°C Average ±0.3°C (-20 to 80°C)
Average ±0.5°C (-40 to -20°C / 80 to 110°C)
Average ±1.0°C (-60 to -40°C / 110 to 155°C)
Measurement Resolution Display 0.1°C
Sensor Thermistor
Recording Interval 1,2,5,10,15,20,30,60 min. (8 choices) 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min. (15 choices)
Logging Capacity 16,000 Readings
Measurement method(*1) Endless (Overwrite from the oldest data when logging capacity is full)
One Time (Stop recording when logging capacity is full)
LCD display Current Temperature, Recording Condition, Battery Life Warning, and Unit of Temperature (°F and°C)
Battery Lithium battery (ER3V M) x 1 (Also available with CR2)
Battery Life(*2) Approximately 2 years Maximum 2 years
Interface Optical Communication (Between a Unit and TR-50C)
Communication Speed 2,400bps (Communication Period of 3 min. or less)
Water Resistance Capacity(*3) IP67 IP64 (*4)
Dimensions H62mm x W47mm x D19mm
Weight 53g (Including battery) 55g (Including battery)
Temperature Resistance of Unit -40 to 80°C
Standard Sensor Built-in TR-5106: (Fluoropolymer-Coated Sensor)
(*1)Lithium Battery (CR-2) can be used for this unit, however the possible temperaure mesurement will be - 20 to 60°C. If you are measuring below -20°C or above 60°C, we recommend the Optional Battery Set TR-00P2
(*2)Battery Life differs depending on measurement environment and battery performance.
(*3)Not for continued immersion.
(*4)The water resistance rating with the sensor or input cable connected is IP64.
Dimensions
TR-51A
TR-51A Dimensions
1.LCD Display
2.Optical Communication Port
3.Back Case
4.Internal temperature sensor
TR-52
TR-52 Dimensions
1.LCD Display
2.Optical Communication Port
3.Back Case
4.Connector
5.Thermistor