TR-74Ui - Illumimance UV Recorder

Standard Kit
  • Manual
    Manual
  • Battery
    Battery
  • Cable
    Cable
  • Illumimance UV Sensor (ISA-3151)
    Illumimance UV Sensor (ISA-3151)
  • Temperature/Humidity Sensor (THA-3151/HHA-3151)
    Temperature/Humidity Sensor (THA-3151/HHA-3151)
  • CD-ROM
    CD-ROM
Setup
TR-74Ui setup
Optional Sensor for TR-74Ui
ISA-3151 (Illuminance UV Sensor)
  ISA-3151
Measurement Items Illuminance UV Intensity
Measurement Range 0 to 130,000lx 0 to 30mW/cm2
Measurement Resolution Minimum: 0.01 lx Minimum: 0.001 mW/cm2:
Measuring Accuracy 10 to 100,000 lx:
±5%(*1)
(at 25°C and 50%RH)
0.1 to 30 mW/cm2
±5%(*1)
(at 25°C and 50%RH)
Relative Spectral
Response
(*2) 260 to 400 nm
Cosine Correction
(cosΘ)
(*3) -
Operating
Environment
Temperature: -10 to 60°C
Humidity: 90%RH or less
(no condensation)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
Sensor Dimensions H23 x W65 x D12.6 mm
Cable Length 1.5 m

*1) Compared to the value measured by the T&D standard sensor for calibration under our calibration light source.
*2) Approximated to the CIE standard response function V (λ).
*3) Within ±1.5% at 10°; Within ±3% at 30°; Within ±10% at 60°; Within ±30% at 80°
Materials:
(1) Polycarbonate
(2) Glass
(3) Vinyl chloride-shielded wire
ISA-3151 (Illuminance UV Sensor)
Unit: mm
THA-3151 (Temperature/Humidity Sensor)
  THA-3151
Measurement Items Temperature Humidity
Measurement Range 0 to 55°C 10 to 95%RH
Measurement Resolution 0.1°C 1%RH
Measuring Accuracy Avg. ±0.3°C ±5%
(at 25°C and 50%RH)
Sensor Response
Time
About 7 min. (90%)
Humidity Hysteresis - ±1%RH (30 to 90%RH)
Operating
Environment
Temperature: 0 to 55°C
Humidity: 95%RH or less
(no condensation)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
Sensor Dimensions H18 x W51.5 x D10 mm
Cable Length 1.5 m

Materials:
(1) Polycarbonate
(2) Vinyl chloride-shielded wire
THA-3151 (Temperature/Humidity Sensor)
Unit: mm
HHA-3151 (Temperature/Humidity Sensor-High-Precision Type)
Measurement Items Temperature Humidity
Measurement Range -30 to 80°C 0 to 99%RH
Measurement Resolution 0.1°C 0.1 %RH
Measurement Accuracy ±0.3°C (at 10 to 40 °C) ±0.5°C (at all other temperatures) ±2.5 %RH(at 25 °C, 10 to 85 %RH) ±4.0 %RH(at 25 °C, 0 to 10 % or 85 to 99 %RH) At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25.
Response Time (90%) Approx. 7 min. Approx. 20 sec.
Sensor Temperature Durability -30 to 80°C
Long Term Stability ±1%RH/yr, ±0.1°C/yr
Humidity Hysteresis - 1.5%RH or lower (*1)
Sensor Dimensions H 19 mm x W 65 mm x D 10 mm
Cable Length 1.5 m
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
*1: When used at temperatures equal to or higher than 0°C.


Materials: ①Polycarbonate ②Vinyl chloride-shielded wire
HHA-3151 (Temperature/Humidity Sensor-High-Precision Type)
Unit: mm
Options for TR-74Ui
TR-1C30
Sensor Extension Cable
Cable Length: 3 m

1. Vinyl chloride-shielded wire

NOTE: Up to 3 extension cables can be connected to one sensor (Temperature/Humidity Sensor THA-3151 / HHA-3151, Illuminance UV Sensor ISA-3151).
TR-1C30
Unit: mm
TR-07K2
Wall Attachment
Included:
Screw x 2
Double-sided Tape x 1
TR-07K2
Unit: mm
US-15C
USB Communication Cable
Cable Length: 1.5 m
US-15C
Unit: mm