TR-71U/72U - Temp/Humidity Data Logger

Standard Kit
  • Manual
    Manual
  • Battery
    Battery
  • Cable
    Cable
  • CD-ROM
    CD-ROM
TR-71U
Standard Kit + TR-0106
TR-71U
TR-72U
Standard Kit + TR-3100 / Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
TR-72U
Setup
TR-71U/72U setup
Optional Temprature Sensor For TR-71U / TR-72U
Possible Measurement Range±-40 to 110°C Sensor Temperature Durability: -50 to 115°C
Measurement Accuracy: Average ±0.3°C(-20 to 80°C) Average±0.5°C(-40 to -20 / 80 to 110°C)
Materials: (1)Thermistor, (2)TPE resin-shielded sensor, (3)TPE resin-shielded wire, (4)M3Screw Hole, (5)Compaction Tube, (6)Stainless Pipe (SUS304)
TR-0106
TPE resin-shielded sensor
Cable Length: 0.6m
Thermal-Constant Time: In the Air: Approx. 75 Sec.
TR-0106
Unit: mm
TR-0206
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In the Air: Approx. 75 Sec
TR-0206
Unit: mm
TR-0306
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In agitated water: Approx. 18 Sec.
TR-0306
Unit: mm
TR-0406
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In agitated water: Approx. 20 Sec.
TR-0406
Unit: mm
TR-0506
Stainless Protection Sensor
Cable Lenth:0.6m
Thermal-Constant Time: In agitated water: Approx. 20 Sec.
TR-0506
Unit: mm
TR-0706
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In agitated water: Approx. 18 Sec.
TR-0706
Unit: mm
Optional Temprature Sensor For TR-71U
Possible Measurement Range: -60 to 155°C / Sensor Temperature Durability: -70 to 180°C
Water Resistant Ability: Splash proof / Measurement Accuracy: Average ±0.5°C(-40 to 80°C)
Average±1.0°C(-60 to -40 / 80 to 100°C) Average ±2.0°C (100 to 155°C)
Materials: (1)Thermistor, (2)Stainless Pipe (SUS316), (3)Fluoropolymer-Coated Compaction Tube, (4)Fluoropolymer-Coated Electrical Wire
TR-1106
Fluoropolymer-Coated Sensor
Cable Length :0.6m
Thermal-Constant Time:
In the Air Approx. 15 Sec.
In agitated water: Approx. 2 Sec.
TR-1106
Unit: mm
TR-1220
Stainless Protection Sensor
Cable Length: 2m
Thermal-Constant Time:
In the Air: Approx. 36 Sec
In agitated water: Approx. 7 Sec.
TR-1220
Unit: mm
TR-1320
Stainless Protection Sensor
Cable Length: 2m
Thermal-Constant Time:
In the Air: Approx. 12 Sec
In agitated water: Approx. 2 Sec.
TR-1320
Unit: mm
Optional Humidity and Temperature Sensor For TR-72U
Humidity Measurement Range: 10 to 95%RH / Temperature Measurement Range: 0 to 50°C
Sensor Durability Range: -10 to 55°C(14 to 131 °F)
Humidity Measurement Accuracy:±5%RH (at 25°C and 50%RH)
Service Life: 1year under normal conditions
Operational Conditions: No dew condensation or water leakage / No contact with organic solvents, solutions or gasses emitted from spoiled foods.
Materials: (1)Temperature / Humidity Sensor, (2)Polypropylene resin, (3)Vinyl Chloride Coated Wire
TR-3110
Humidity and Temperature Sensor
Cable Length:1m
Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
TR-3110
Unit: mm
TR-3100
Humidity and Temperature Sensor
Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
TR-3100
Unit: mm
Options for TR-71U / TR-72U
TR-1C30
Sensor Extension Cable
Cable Length: 3m

1.Vinyls Chloride Coated Wire

Note: Only one cable per sensor. Can not be used with Temperature / Humidity sensor TR-3110 or TR-3100.
TR-1C30
Unit: mm
TR-5C10
TR-3100 Extension Cable

1.Vinyl Chloride Coated Wire

Note: Only one cable per TR-3100 sensor. Cannot be used with Humidity / Temp Sensor TR-3110.
TR-5C10
Unit: mm
TR-07K2
Wall Attachment
Included:
Wall Mount Screws x 2
Double-Sided Adhesive Tape x 1
TR-07K2
Unit: mm
TR-07C
Serial Communication Cable
Cable Length:1.5m

Connector Type: Specialized Connector D-sub9pin
TR-07C
Unit: mm
TR-4C10
Serial Communication Cable
Cable Length: 1m

For communication with TR-57C/RTR-57C
TR-4C10
Unit: mm
TR-6C10
Serial Communication Cable
Cable Length: 1m

For communication with TR-57U/RTR-57U
TR-6C10
Unit: mm
US-15C
USB Communication Cable
Cable Length: 1.5m
US-15C
Unit: mm