WDR-3 - Network-Dedicated Instrumentation Data Logger

Specifications
WDR-3
Measurement Items Analog Voltage, ON/OFF Signal
Number of Channels 4 Ch (2 Ch for Analog Signal/ 2 Ch for ON/OFF Signal)
Analog Signal Input Number of Input Channels: 2 Ch for Analog Signal (Common Ground)
Signal Input: Voltage Input
Input voltage Range:0 to 5V (Input Resistance: 1MΩ)
Measurement Resolution: 4.88mV (10bit)
Measurement Cycle: 1min (average of 6 samplings x 10 sec.)

Recording Method:
Instantaneous Value Recording Method:
Data Measurement for each Recording Interval
Average Value Recording Method:
Average of Data Measurements for Recording Interval

Recording Interval:
6 intervals to select from: 10,20,30,40,50 60 min.
Logging Capacity: 2,880 data sets (One data set consists of readings for 2 channels for Analog Signal.)
Recording Mode: Endless Mode (Overwrite oldest data when capacity is full)
Monitoring Function: A warning can be issued when a measurement exceeds a set upper or lower limit for each channel during the set monitoring interval.
ON/OFF Signal Input Measurement Channels:
2 Ch for On / Off Signal (Common Ground)
Input Signal: Voltage Input, Contact Input
[Input voltage Range: 0 to 15V
Lo(on) Detection Voltage: 1V or below
Hi(off) Detection Voltage: 3V or above
OFF Detection Time: 50ms or above
ON Detection Time: 50ms or above
Pull up: 5V 4.7k


Recording Method
Pulse Recording Method:
Records the number of pulses during the set recording interval (number of rising signals)
Polarity Change Recording Method:
Records the time when a rising/falling signal occurs

Recording Interval:
Pulse Number Recording Method: 6 intervals to select from: 10,20,30,40,50 60 minutes

Polarity Change Recording Method:
Measurement occurs every second without regard to recording interval and the date and time of any change is recorded.

Logging Capacity:
Pulse Number: 2,880 readings
Polarity Change: 760 readings

Recording Mode:
Endless Mode(Overwrite oldest data when capacity is full)

Monitoring Function:
Make monitoring time settings and upper / lower limit settings for the number of pulse signal changes for each channel, when those limit settings are exceeded, a warning notice is sent. It is also possible to make condition settings for signals, and when changes occur outside those conditions during the monitoring period, a warning is sent.
Power AC Adaptor
External Contact Output (Warning Output) Contact Output via Photo Repeater
When operating the warning function
OFF-State Voltage: AC/DC 50V or below
ON-State Current: 0.1A or below
ON-State Resistance: MAX 35Ω
Type of Communication Wired LAN (100/10BASE-T) *1
Operating Environment Temperature: 0 to 50°C / Humidity: 20 to 80%RH (No condensation)
Dimensions H83mm x W102mm x D28mm
Weight of Main Unit About 125g
Accessories included in package Software Set x1
AC Adaptor (AD-05C1 or AD-0605) x1
LAN Cable (LN-20W)x1
Introductory Guide (including Warranty) x1
The WDR-3 is designed solely for network communication. It does not include any RS-232 or USB communication interface. To use this product, please make sure to connect it to a network. Moreover, in order to use this product via the Internet, the user will need other devices, such as a router, and must first make necessary arrangements such as establishing an account with an Internet Service Provider for a line and obtaining a fixed IP address, domain, etc.

*1 If you already have the following wireless LAN card, please use as directed. The wireless LAN card which has been tested and proven compatible with WDR-3 is the Dark Marketing Corporation's Wireless LAN card "XI-815".The production and sales of this card have been discontinued.

When making settings in a WDR-3 without any settings already made (when purchased or after resetting), it is necessary to carry out these settings using a wired LAN connection. After having made all the necessary settings via the wired connection, it is possible to use a wireless LAN connection.
Dimensions
 Dimensions
1:Power LED
2:CF Card Slot
3:Reset Button
4:External Output Terminal (Warning Output)
5:Analog Signal Input Terminal (Voltage [Max 5V] Input)
6:ON/OFF Signal Input Terminal (Contact or Voltage [Max 15V] Input
7:AC Adaptor Jack 8:10/100Base-T Terminal (RJ45)
9:Alarm LED (ON/OFF CH1)
10:Alarm LED (ON/OFF CH2)
11:Alarm LED (Analog CH1/CH2)